Alex Waithera10 min readUpdated

    Hydrogen Compression Cost per kg: A Worked 100 MW Example

    Hydrogen compression cost at a large electrolysis plant is usually measured in cents per kilogram, not dollars. In the worked 100 MW example below, built on U.S. Department of Energy (DOE) compressor data, compressing hydrogen from 30 bar to 100 bar for a pipeline adds about 7 cents per kg, while starting from near-atmospheric pressure adds about 30 cents.

    Short answer: for a 100 MW electrolyzer running 5,000 full-load hours on $40/MWh power, compression from 30 bar to 100–500 bar costs roughly $0.07–0.18 per kg, and from 1 bar to 100 bar about $0.30 per kg, on stated illustrative assumptions. The electrolyzer's outlet pressure and the plant's scale move the cost far more than the final delivery pressure does. Small refueling-station compressors are a different story, at well over $1 per kg.

    This article sits in our hydrogen cost cluster. If you are new to how cost lines combine into one number, start with our guide to what LCOH is and how it is calculated.

    Why does compression matter to a hydrogen project?

    Compression is the step between the electrolyzer and almost every buyer: a pipeline, a storage vessel, a tube trailer or a refueling station. It costs electricity every hour and capital up front, and it is easy to leave out of a first LCOH estimate.

    For scale, DOE's 2022 status value for a PEM electrolysis system is 55 kWh of electricity per kg of hydrogen (DOE, Technical Targets for PEM Electrolysis, page updated 29 May 2026). In our example, compression adds between 1.4% and 5.6% to that electricity use. That is small, but at a plant making 9,000 tonnes a year it is still 7,000–28,000 MWh a year of extra power.

    What does DOE say compressors cost and use?

    DOE publishes status values for three classes of hydrogen compressor (DOE, Technical Targets for Hydrogen Delivery). The FY2015 status values are:

    Compressor class (DOE FY2015 status) Duty Uninstalled capital cost Energy use (kWh/kg) Annual maintenance (% of installed capital)
    Pipeline, terminal and geologic storage ~200,000 kg/day, 20 bar in, 100 bar out $5.5 million 0.82 6%
    Tube-trailer terminal ~300 kg/h, 100 bar in, 550 bar out $450,000 1.1 2%
    Fueling station ~100 kg/h peak, 100 bar pipeline supply, 950 bar out $275,000 1.6 8%

    Dividing each capital cost by its motor duty (flow times energy use) gives a rough cost per kW of compressor power. On our arithmetic, the large pipeline compressor works out to about $805/kW (around 6,833 kW) and the station compressor to about $1,719/kW (160 kW). Small machines cost about twice as much per kW, and they also run fewer hours.

    Station compression is where the published costs are high. A 2014 peer review for DOE by the National Renewable Energy Laboratory put compression at about $1.48–1.54 per kg in its base case, 55% to 65% of the station's compression, storage and dispensing cost (NREL, Hydrogen Station Compression, Storage, and Dispensing Technical Status and Costs, NREL/BK-6A10-58564). The same review reports measured station compression energy of roughly 1.6 to 18 kWh/kg, and uses a 65% isentropic efficiency as its base case, with 50% and 80% as the pessimistic and optimistic cases.

    How much energy does compressing hydrogen take?

    Compression energy grows with the logarithm of the pressure ratio, so the starting pressure matters as much as the end pressure. Going from 1 to 10 bar takes about the same ideal work as going from 30 to 300 bar.

    We estimate energy use with a standard multi-stage, intercooled model: ideal-gas hydrogen at 40 °C inlet, a pressure ratio of no more than 3 per stage, 65% isentropic efficiency (NREL's base case) and a 95% efficient motor. As a check, this method gives 1.05 kWh/kg for DOE's 20-to-100-bar pipeline duty, above DOE's 0.82 kWh/kg. Our results are therefore on the conservative side for large machines.

    What is the hydrogen compression cost for a 100 MW plant?

    All inputs are illustrative assumptions, not quotes, project data or H2Hub outputs.

    Stated assumptions:

    Results: compression cost per kg

    Case (illustrative) Pressure Stages Energy (kWh/kg) Motor power (kW) Installed capital ($m) Electricity (¢/kg) Capital recovery (¢/kg) Maintenance (¢/kg) Total (¢/kg)
    A. Pressurized outlet to pipeline 30 → 100 bar 2 0.76 1,390 2.2 3.1 2.9 1.5 7.4
    B. Atmospheric outlet to pipeline 1 → 100 bar 5 3.07 5,579 9.0 12.3 11.5 5.9 29.7
    C. Fill 250-bar storage or trailers 30 → 250 bar 2 1.44 2,623 4.2 5.8 5.4 2.8 14.0
    D. Fill 500-bar trailers 30 → 500 bar 3 1.88 3,417 5.5 7.5 7.1 3.6 18.2

    Totals may differ from the sum of the parts because of rounding.

    What the numbers say

    The contrast with refueling stations is scale and use. NREL's $1.48–1.54/kg station figure comes from compressors of tens of kilograms per hour, at roughly twice the cost per kW of a large machine, compressing to 950 bar and running only when vehicles need fuel.

    What does this example leave out?

    This is a screening estimate, not a compressor selection. It leaves out:

    Try it in H2Hub

    Start a free H2Hub project for your site, with no account or card needed, using this example's inputs: a 100 MW electrolyzer, 55 kWh/kg, $40/MWh power and 5,000 full-load hours. Then add the compression line from the table above to the plant-gate cost per kg you get, and see how much of your buyer's price it uses.

    Your first full project and its PDF report are free per account, and downloading that PDF needs a free sign-in. Re-running with new inputs, such as more operating hours, or adding a second project requires a subscription. Subscribers can explore compression, storage and transport pathways in the Storage & Transport Lab, a subscriber tool; signed-out visitors see an introduction.

    A note on pre-feasibility

    These figures are calculations from public DOE data and stated assumptions. They are not compressor quotes, engineering designs or H2Hub-generated results. Before relying on a compression cost, get vendor quotes for your flow, suction and discharge pressures, duty cycle and redundancy requirement, and have a qualified engineer review the design.

    Frequently asked questions

    How much does it cost to compress hydrogen per kg?

    At large plant scale, our worked example gives about $0.07–0.18 per kg to compress from 30 bar to 100–500 bar, and about $0.30 per kg from near-atmospheric pressure to 100 bar. At refueling stations, NREL's 2014 review put compression at about $1.48–1.54 per kg in its base case.

    How much energy does it take to compress hydrogen?

    DOE's FY2015 status values are 0.82 kWh/kg for a large 20-to-100-bar pipeline compressor and 1.1 kWh/kg for a 100-to-550-bar trailer-filling compressor. Our conservative model gives 0.76–3.07 kWh/kg across the four cases, and NREL reports measured station values from about 1.6 to 18 kWh/kg.

    Does electrolyzer outlet pressure matter for compression cost?

    Yes, more than any other choice in our example. Starting at 1 bar instead of 30 bar raised compression from 7.4 to 29.7 cents per kg for the same 100-bar delivery, because the first pressure steps take the most work per bar.

    Why is compression at hydrogen stations so expensive?

    Station compressors are small, cost more per kW, compress to around 950 bar and run only when vehicles fill. NREL's review found compression was 55% to 65% of station compression, storage and dispensing cost, and called for better data on compressor failure rates and repair costs.

    Primary sources and further reading

    1. U.S. Department of Energy — DOE Technical Targets for Hydrogen Delivery. Compressor capital cost, energy use and maintenance status values (FY2015) and targets. Checked 25 November 2026.
    2. National Renewable Energy Laboratory — Hydrogen Station Compression, Storage, and Dispensing Technical Status and Costs, NREL/BK-6A10-58564, G. Parks, R. Boyd, J. Cornish and R. Remick, May 2014.
    3. U.S. Department of Energy — Technical Targets for Proton Exchange Membrane Electrolysis, page updated 29 May 2026.
    4. U.S. Department of Energy — Program Record 18003: Current Status of Hydrogen Delivery and Dispensing Costs and Pathways to Future Cost Reductions, N. Rustagi, A. Elgowainy and J. Vickers, December 2018.

    Editorial verification: 2026-11-25. Worked examples are calculations from stated assumptions, not forecasts, market prices or H2Hub-generated results.

    Sources

    Explore project tools

    Related articles

    Test your own project assumptions

    H2Hub models power, water and hydrogen costs together — every figure shows its source, date and confidence.

    Model your plant-gate hydrogen cost in H2Hub — start free

    H2Hub produces preliminary project-development analysis. It is not a substitute for licensed engineering, FEED, due diligence or investment advice.