Electrolyser dispatch and technology fit

    Vendor models

    64 of 64 models · 41 brands
    SelectBrand / modelTechnologyUnit MWH₂ kg/hSpecific energy kWh/kg / basisMin / max load %Pressure barPurity %Stack life hWater L/kgStatusSource / review
    Siemens EnergyElyzer P-300 (formerly Silyzer 300)Prefabricated skids; 24-stack array; indoorPEM17.5335—
    Reference used
    —
    40 / 100—99.9998000010commercial
    A

    No kWh/kg published – H2Hub reference used

    Source
    Source notes

    Siemens Energy Electrolyzer Brochure (2026) · Accessed 2026-11-05

    Plant efficiency >75.5% (basis not stated) so kWh/kg blank; min load per stack; 80k h design life; pressure customised

    Siemens EnergyElyzer P-360Modular skids; ~50 MW; 48x20 mPEM5092055.5 · upper bound
    Used in simulation
    system AC incl. power electronics; upper bound
    40 / 1001099.999—10early-commercial
    A

    Source
    Source notes

    Siemens Energy Elyzer P-360 Factsheet (2026) · Accessed 2026-11-05

    Pressurised P-300 successor; 10 bara; approx figures

    Nel HydrogenMC500Containerised 40ft + 20ft powerPEM2.544.2356.73
    Used in simulation
    system; stack 52.28
    10 / 1003099.95—15.9commercial
    A

    Older document

    Source
    Source notes

    Nel MC Series Spec Sheet Rev G (2021) · Accessed 2026-11-05

    492 Nm3/h and 5.1 kWh/Nm3 converted; 2021 sheet, current sales not confirmed

    ITM PowerNEPTUNE VContainerised; 8 stacksPEM59055.9
    Used in simulation
    system AC incl. water purification + BoP; BOL
    12.5 / 10030———commercial
    A

    Source
    Source notes

    ITM Power NEPTUNE V Spec Sheet 2.8 · Accessed 2026-11-05

    Purity <5 ppm H2O/O2 (ISO 14687)

    ITM PowerNEPTUNE IIContainerised; 3 stacksPEM23557
    Used in simulation
    system AC incl. water purification + BoP; BOL
    25 / 10030———commercial
    A

    Source
    Source notes

    ITM Power NEPTUNE II Spec Sheet 2.13 · Accessed 2026-11-05

    Purity <5 ppm H2O/O2

    ITM PowerPOSEIDONSkid-mounted; 30 TRIDENT stacksPEM2036055.9
    Used in simulation
    system AC incl. water purification + BoP; BOL
    20 / 10031———commercial
    A

    Source
    Source notes

    ITM Power POSEIDON Data Sheet 2.7 · Accessed 2026-11-05

    Water-saturated output

    ITM PowerTRIDENT (2 MW skid)Skid with 3 stacksPEM236—
    Reference used
    —
    25 / 10031———commercial
    C

    No kWh/kg published – H2Hub reference used; Not from manufacturer

    Source
    Source notes

    TRIDENT Data Sheet 2.1 A (third-party copy) · Accessed 2026-11-05

    Third-party copy of ITM sheet; no specific energy

    Plug PowerGenEco 10 MWModular; ~117 m2PEM10179.849.9
    Reference used
    average stack; BOL not stated
    — / —4099.999—13commercial
    A

    Vendor kWh/kg is not a system-level figure – shown, but H2Hub reference efficiency used in simulation

    Source
    Source notes

    Plug GenEco 10 MW datasheet · Accessed 2026-11-05

    2000 Nm3/h converted; STACK figure, not system

    Accelera (Cummins)HyLYZER 1000-30Containerised; 2 stacksBrowse-only · No – discontinuedPEM59052
    Reference used
    system BOL nominal
    15 / 1003099.9—9discontinued
    B

    Source
    Source notes

    Accelera HyLYZER 1000 product page · Accessed 2026-11-05

    Cummins halted new electrolyzer sales Feb 2026 (trade press)

    Electric HydrogenHYPRPlantOpen-air integrated plant 75-120 MWPEM100190045.2–54.3 · range
    Used in simulation
    system BOL at AC into plant transformers; range
    — / —3299.9—13commercial
    A

    Older document

    Source
    Source notes

    EH2 Technical Specification Sheet (Aug 2023) · Accessed 2026-11-05

    Peak BOL output; 2023 sheet

    Quest One (MAN)MHP 10 MW blockSkid-mounted block; indoorPEM10191.551
    Reference used
    stacks + converters; BOL; HHV
    10 / 1003099.999——commercial
    B

    Vendor kWh/kg is not a system-level figure – shown, but H2Hub reference efficiency used in simulation

    Source
    Source notes

    Quest One MHP product page · Accessed 2026-11-05

    2130 Nm3/h converted; 5.0 purity with option; formerly H-TEC Systems

    OhmiumLotus MK3Outdoor modular rack unitsPEM——48
    Used in simulation
    system AC BOL
    — / —————commercial
    B

    Source
    Source notes

    Ohmium Products page · Accessed 2026-11-05

    Only specific energy published

    HystarVega 1000ContainerisedPEM592.150.7
    Used in simulation
    system incl. power unit; 100% load; 4 barg; BOL
    0 / 10045———early-commercial
    B

    Source
    Source notes

    Hystar Vega product page · Accessed 2026-11-05

    Headline 48.8; 52.7 at 30 barg; stack 47.5

    HystarOrion 20000Skid-based 20 MW clusterPEM2036848.2
    Reference used
    cluster; basis unclear
    — / —————early-commercial
    B

    Vendor kWh/kg is not a system-level figure – shown, but H2Hub reference efficiency used in simulation; Published figures inconsistent – confirm with vendor

    Source
    Source notes

    Hystar Orion product page · Accessed 2026-11-05

    CHECK: 48.2 kWh/kg inconsistent with 20 MW / 368 kg/h

    Sungrow HydrogenPEM 500 Nm3/h40ft containerPEM—44.9550.06
    Used in simulation
    system AC BOL nominal; stack DC 47.83
    5 / 1103099.999—10.01commercial
    A

    Source
    Source notes

    Sungrow PEM datasheet (Feb 2025) · Accessed 2026-11-05

    500 Nm3/h converted; purity after purification

    thyssenkrupp nucerascalum 20 MW AWE unitPrefabricated skid-mounted modular plantAlkaline20359.650.06
    Reference used
    DC at start-up; expected values
    10 / 1000.399.9——commercial
    A

    Vendor kWh/kg is not a system-level figure – shown, but H2Hub reference efficiency used in simulation

    Source
    Source notes

    thyssenkrupp nucera Green Hydrogen brochure (Oct 2024) · Accessed 2026-11-05

    4000 Nm3/h; 4.5 kWh/Nm3 DC expected; near-atmospheric

    Nel HydrogenA485 (A-Series atmospheric)Modular atmospheric systemAlkaline2.543.5850.06
    Reference used
    stack; DC/AC not stated
    15 / 1000.03———commercial
    A

    Vendor kWh/kg is not a system-level figure – shown, but H2Hub reference efficiency used in simulation

    Source
    Source notes

    Nel A Series Spec Sheet DOC001974_03 · Accessed 2026-11-05

    485 Nm3/h max; 50 ±1.1 kWh/kg at stack, 100% load; turndown 15-100%; no system figure published

    Nel HydrogenAWE 100 Standard PlantStandard 100 MW atmospheric plantAlkaline1001744.0651.1
    Used in simulation
    plant AC; nominal
    15 / 1000.0399.99——commercial
    A

    Source
    Source notes

    Nel AWE 100 Standard Plant Solution · Accessed 2026-11-05

    Stack DC 49 kWh/kg; plant 51.1; purity with optional purification

    Nel HydrogenPressurised Alkaline (PAE) 25 MWOutdoor, 230 m2Alkaline25416.6950.8–53.2 · range
    Used in simulation
    system BOL
    12.5 / 1001599.5——early-commercial
    A

    Source
    Source notes

    Nel datasheet PAE (May 2026) · Accessed 2026-11-05

    Stack BOL 48.8-51.2; degradation 1-1.5%/yr; launched May 2026

    John Cockerill HydrogenDQ1000Pressurised single-stack unitAlkaline589.9—
    Reference used
    stack DC 44.49-47.83 kWh/kg; system not stated
    40 / 1003099.8—10.23commercial
    A

    No kWh/kg published – H2Hub reference used; Older document

    Source
    Source notes

    John Cockerill DQ1000 datasheet (2023) · Accessed 2026-11-05

    1000 Nm3/h; 5 MW plant AC; 99.999% after purification

    Stargate HydrogenAurora 10 MW moduleOutdoor module, 2x5 MW stacksAlkaline10—49 · upper bound
    Reference used
    stack
    — / —————early-commercial
    C

    Vendor kWh/kg is not a system-level figure – shown, but H2Hub reference efficiency used in simulation; Not from manufacturer

    Source
    Source notes

    H2 Tech: Stargate Aurora (Oct 2025) · Accessed 2026-11-05

    Trade press; no maker datasheet

    McPhyMcLyzer 800-30Core moduleBrowse-only · No – discontinuedAlkaline471.9250.06
    Reference used
    DC nominal
    — / —30———discontinued
    C

    Vendor kWh/kg is not a system-level figure – shown, but H2Hub reference efficiency used in simulation; Not from manufacturer; Older document

    Source
    Source notes

    McPhy McLyzer portfolio (2020) · Accessed 2026-11-05

    McPhy liquidated 2025; John Cockerill took most assets

    SunfireHyLink Alkaline 23 (50 MW)Outdoor skid module, 10x5 MW stacksAlkaline50100046.5–52.3 · range
    Used in simulation
    total AC
    20 / 1003099.8——early-commercial
    A

    Source
    Source notes

    Sunfire HyLink Alkaline 23 fact sheet (Apr 2026) · Accessed 2026-11-05

    50 MW DC rating; 67% LHV DC; stack mechanical life 10 yr; ramp 4%/s

    SunfireHyLink Alkaline 22 (10 MW)10 MW moduleAlkaline10——
    Reference used
    stack 67% LHV DC; no kWh/kg
    — / —30———commercial
    B

    No kWh/kg published – H2Hub reference used

    Source
    Source notes

    Sunfire HyLink Alkaline page · Accessed 2026-11-05

    No fact sheet; output not stated

    LONGi HydrogenALK G seriesStandardised seriesAlkaline—107.88–269.747.83–50.06 · range
    Reference used
    DC
    30 / 11016———commercial
    B

    Vendor kWh/kg is not a system-level figure – shown, but H2Hub reference efficiency used in simulation; Published life figure is service/design life, not stack life – H2Hub reference stack life used

    Source
    Source notes

    LONGi ALK G product page · Accessed 2026-11-05

    1200-3000 Nm3/h; 200000 h is service life not stack life

    LONGi HydrogenALK Hi1 Plus 1000Single unitAlkaline—89.945.61
    Reference used
    DC
    30 / 1101699.999——commercial
    A

    Vendor kWh/kg is not a system-level figure – shown, but H2Hub reference efficiency used in simulation

    Source
    Source notes

    LONGi Hi1 datasheet · Accessed 2026-11-05

    <=4.1 kWh/Nm3; purity after purification

    Sungrow HydrogenALK 1000 Nm3/hSeparation + purification skidsAlkaline—89.951.17
    Used in simulation
    system AC BOL nominal
    25 / 1101699.8—10.01commercial
    A

    Source
    Source notes

    Sungrow ALK datasheet (Feb 2025) · Accessed 2026-11-05

    Stack DC BOL 50.06; ramp 5%/s

    Sungrow HydrogenALK 500 Nm3/hSeparation + purification skidsAlkaline—44.9551.72
    Used in simulation
    system AC BOL nominal
    25 / 1101699.8—10.01commercial
    A

    Source
    Source notes

    Sungrow ALK datasheet (Feb 2025) · Accessed 2026-11-05

    Stack DC BOL 50.06

    Trina HydrogenOne Series AWE 2000Single unitAlkaline—179.844.49–48.94 · range
    Reference used
    basis not stated
    30 / 11016———commercial
    C

    Vendor kWh/kg is not a system-level figure – shown, but H2Hub reference efficiency used in simulation; Not from manufacturer

    Source
    Source notes

    Hyfindr listing: AWE 2000 · Accessed 2026-11-05

    Marketplace source, not manufacturer

    Bloom EnergyBloom Electrolyzer (1.2 MW block)modular block in 1.2 MW stepsSOEC1.23237.5
    Used in simulation
    system; electricity; external steam supplied (4.5-5.5 barg, 150-200 C), steam heat not quantified
    — / —0.025——10.5commercial
    A

    Needs external steam/heat; Older document

    Source
    Source notes

    Bloom Energy Electrolyzer datasheet (Dec 2023) · Accessed 2026-11-05

    25 mbar(g) output; product gas 85% H2/15% H2O (not dried); datasheet states 37.5+

    Bloom EnergyBloom Electrolyzer (4 MW)modularSOEC410037.5
    Used in simulation
    system; steam/heat basis not stated
    — / —————commercial
    B

    Needs external steam/heat

    Source
    Source notes

    Bloom Energy - Electrolyzers · Accessed 2026-11-05

    Over 2.4 t/day (100 kg/h is lower bound); 37.5 from INL pilot; SOEC range 37-44 stated

    SunfireHyLink SOEC (GEN 3)pre-assembled outdoor module 34 x 7.5 mSOEC10291—
    Reference used
    system AC; 89% LHV expected GEN 3; needs LP steam >150 C
    50 / 100————early-commercial
    B

    No kWh/kg published – H2Hub reference used; Needs external steam/heat

    Source
    Source notes

    Sunfire HyLink SOEC product page · Accessed 2026-11-05

    No kWh/kg published (efficiency only); ramp 10%/min; ISO 14687 Grade B after drying

    TopsoeSOEC core (demo)cell>stack>core>sectionBrowse-only · No – demo figures, no product datasheetSOEC0.35—36
    Reference used
    core level; electricity; demo; upper bound
    — / 1053.5———demo
    B

    Vendor kWh/kg is not a system-level figure – shown, but H2Hub reference efficiency used in simulation; Needs external steam/heat

    Source
    Source notes

    Topsoe SOEC demo results · Accessed 2026-11-05

    Demo figures not datasheet; <36 kWh/kg; 2,250 h test only

    ElcogenSOEC stackstack componentBrowse-only · No – not a sold productSOEC——33
    Reference used
    stack claim; electricity
    — / —————announced
    C

    Vendor kWh/kg is not a system-level figure – shown, but H2Hub reference efficiency used in simulation; Needs external steam/heat; Not from manufacturer

    Source
    Source notes

    Hydrogen Insight - Elcogen 350MW factory · Accessed 2026-11-05

    Trade press; stack supplier only; company claim

    Ceres10 MW pressurised SOEC module (Shell design)module (licensed design)Browse-only · No – not a sold productSOEC10—36
    Reference used
    module level; target
    — / —————announced
    C

    Vendor kWh/kg is not a system-level figure – shown, but H2Hub reference efficiency used in simulation; Needs external steam/heat; Not from manufacturer

    Source
    Source notes

    Ceres signs contract with Shell · Accessed 2026-11-05

    Licensor; target value, not product

    EnapterAEM Nexus 1000containerised 40 ftBrowse-only · Library only – no AEM reference profile yetAEM0.933218.251.3
    Reference used
    system incl. utilities; BoL full load
    8.5 / 1003199.5—8.98commercial
    A

    Source
    Source notes

    Datasheet AEM Nexus 1000 (15.06.2026) · Accessed 2026-11-05

    202 Nm3/h; 4.61 kWh/Nm3; purity up to 99.999% with dryer

    EnapterAEM Flex 120skid 6 x 2.5 mBrowse-only · Library only – no AEM reference profile yetAEM0.1122.1651.3
    Reference used
    system incl. utilities; BoL full load
    12 / 1003199.5—8.98commercial
    A

    Source
    Source notes

    Datasheet AEM Flex 120 (15.06.2026) · Accessed 2026-11-05

    24.1 Nm3/h; 4.61 kWh/Nm3

    EnapterEL 4.1 (AC/LC)19-inch rack 6UBrowse-only · Library only – no AEM reference profile yetAEM0.00240.04553.4
    Reference used
    basis not stated; BoL
    — / —3599.9—9.34commercial
    A

    Vendor kWh/kg is not a system-level figure – shown, but H2Hub reference efficiency used in simulation

    Source
    Source notes

    Data Sheet EL 4 AC LC · Accessed 2026-11-05

    0.5 Nm3/h at 4.8 kWh/Nm3 converted

    PERIC Hydrogen (718th Institute)CDQ series (CDQ16-CDQ1000)skid-mountedAlkaline—1.8–179.847.83 · upper bound
    Reference used
    DC; stack vs system not stated
    — / ——99.8——commercial
    B

    Vendor kWh/kg is not a system-level figure – shown, but H2Hub reference efficiency used in simulation

    Source
    Source notes

    PERIC Hydrogen - Alkaline type · Accessed 2026-11-05

    20-2000 Nm3/h; <=4.3 kWh/Nm3 DC; purity >99.8% initial

    ShuangliangSLZQ-2000stack 6.0x2.5x2.8 mAlkaline—179.843.38–50.06 · range
    Reference used
    DC; stack vs system not stated
    20 / 1104099.9999——commercial
    B

    Vendor kWh/kg is not a system-level figure – shown, but H2Hub reference efficiency used in simulation; Published life figure is service/design life, not stack life – H2Hub reference stack life used

    Source
    Source notes

    Shuangliang - Alkaline Water Electrolyzer · Accessed 2026-11-05

    3.9-4.5 kWh/Nm3 DC; purity with purification; 1.6-4.0 MPa; service life >=160000 h (not stack life); pressure as published: 16-40

    Cockerill Jingli HydrogenDQ-1000/1.6pressurised filter-press bipolarAlkaline———
    Reference used
    DC; stack vs system not stated
    — / —16———commercial
    B

    No kWh/kg published – H2Hub reference used

    Source
    Source notes

    Cockerill Jingli Hydrogen - Alkaline electrolysis · Accessed 2026-11-05

    Output and energy units unclear on source, left blank; 21 models DQ-2 to DQ-1500

    Hygreen EnergyHG200integrated frameAlkaline117.98—
    Reference used
    —
    30 / 1103299.999——commercial
    B

    No kWh/kg published – H2Hub reference used

    Source
    Source notes

    Hygreen Energy - Alkaline · Accessed 2026-11-05

    200 Nm3/h; line-level load and pressure; no energy figure; pressure as published: <32

    Hygreen EnergyPEM electrolyser linecontainerised or custom plantPEM1.5—47.83
    Reference used
    DC; stack vs system not stated
    5 / 110————commercial
    B

    Vendor kWh/kg is not a system-level figure – shown, but H2Hub reference efficiency used in simulation

    Source
    Source notes

    Hygreen Energy - PEM · Accessed 2026-11-05

    Stack up to 1.5 MW; 4.3 kWh/Nm3; power as published: <1.5

    Hygreen EnergyAEM electrolyser linecontainerised turnkeyBrowse-only · Library only – no AEM reference profile yetAEM0.58.9948.94
    Reference used
    DC; stack vs system not stated
    10 / 120————early-commercial
    B

    Vendor kWh/kg is not a system-level figure – shown, but H2Hub reference efficiency used in simulation

    Source
    Source notes

    Hygreen Energy - AEM · Accessed 2026-11-05

    Stack up to 500 kW / 100 Nm3/h; 4.4 kWh/Nm3; status judged; power as published: <0.5

    Shanghai Electric (Hydrogen Era)QQSD-Z seriesAlkaline—4.5–179.847.39
    Reference used
    DC; stack vs system not stated
    20 / 167————early-commercial
    C

    Vendor kWh/kg is not a system-level figure – shown, but H2Hub reference efficiency used in simulation; Not from manufacturer

    Source
    Source notes

    Huanqiu Tech on Shanghai Electric QQSD-Z · Accessed 2026-11-05

    Trade press (Mar 2024); 50-2000 Nm3/h; 4.26 kWh/Nm3 DC rated

    Mingyang HydrogenMYH-K-1000Alkaline———
    Reference used
    DC; stack vs system not stated
    20 / 120————early-commercial
    C

    No kWh/kg published – H2Hub reference used; Not from manufacturer

    Source
    Source notes

    SMM: Mingyang MYH-K-1000 Frontrunner evaluation · Accessed 2026-11-05

    Trade press (Mar 2026); 1000 Nm3/h class; energy unit basis unclear

    Guofu Hydrogen2000 Nm3 alkaline unitAlkaline——46.72 · upper bound
    Reference used
    DC; stack vs system not stated
    20 / —————early-commercial
    C

    Vendor kWh/kg is not a system-level figure – shown, but H2Hub reference efficiency used in simulation; Not from manufacturer

    Source
    Source notes

    SMM: Guofu 2000 Nm3 alkaline electrolyser · Accessed 2026-11-05

    Trade press (Sep 2026); <=4.2 kWh/Nm3 DC at 4000 A/m2

    CRRCWide Power Range Adjustable Electrolyzer (1000 Nm3/h)electrolyser + separation/purification unitAlkaline—89.948.94 · upper bound
    Reference used
    DC; stack vs system not stated
    25 / 1101699.999——commercial
    B

    Vendor kWh/kg is not a system-level figure – shown, but H2Hub reference efficiency used in simulation

    Source
    Source notes

    CRRC Wide Power Range Adjustable Electrolyzer · Accessed 2026-11-05

    CRRC group domain (Apr 2025); <=4.4 kWh/Nm3 DC; purity after purification

    SPIC Hydrogen Energy Technology500 Nm3/h PEM electrolyserPEM—44.9548.94
    Reference used
    basis not stated
    — / —————early-commercial
    C

    Vendor kWh/kg is not a system-level figure – shown, but H2Hub reference efficiency used in simulation; Not from manufacturer

    Source
    Source notes

    FuelCellChina: SPIC 500 Nm3/h PEM certification · Accessed 2026-11-05

    Trade press (Oct 2024); 4.4 kWh/Nm3 at 1.8 A/cm2

    Shanghai H-Ray S&TPEM stack 100-250 Nm3/hstackPEM—8.99–22.4845.61
    Reference used
    DC; stack vs system not stated
    10 / 120————commercial
    C

    Vendor kWh/kg is not a system-level figure – shown, but H2Hub reference efficiency used in simulation; Published life figure is service/design life, not stack life – H2Hub reference stack life used; Not from manufacturer

    Source
    Source notes

    Hyfindr: H-Ray PEM stack · Accessed 2026-11-05

    Marketplace; 4.1 kWh/Nm3 DC; design lifetime >=80000 h (not stated as stack life)

    Asahi KaseiAqualyzer-C3containerisedAlkaline1——
    Reference used
    —
    — / —————commercial
    C

    No kWh/kg published – H2Hub reference used; Not from manufacturer

    Source
    Source notes

    Asahi Kasei containerised electrolyser Finland (Business Wire) · Accessed 2026-11-05

    Press release (Mar 2026); 1 MW class; 400 kg/day; C3 range 1-7.5 MW

    Kanadevia (formerly Hitachi Zosen)HYDROSPRING 200 Nm3/hpackage unitPEM—17.9855.62
    Reference used
    AC; stack vs system not stated
    — / —8.599.999—11.12commercial
    B

    Vendor kWh/kg is not a system-level figure – shown, but H2Hub reference efficiency used in simulation

    Source
    Source notes

    Kanadevia - Hydrogen Generator · Accessed 2026-11-05

    5.0 kWh-AC/Nm3; 0.8-0.85 MPaG; pressure as published: 8-8.5; purity as published: 99.9-99.999

    G-PhilosModular P2G ALK Linked 1Mmodular 10 kW stack modulesAlkaline117.9853.88
    Used in simulation
    system (stack 50.07); DC/AC not stated
    — / —799.999—10commercial
    C

    Published figures inconsistent – confirm with vendor; Not from manufacturer

    Source
    Source notes

    Hyfindr: G-Philos ALK Linked · Accessed 2026-11-05

    Marketplace; listing internally inconsistent; status not stated

    Nel HydrogenPEM 100 Standard PlantStandard outdoor plant; 96 x 69 mPEM100181655.6
    Used in simulation
    system – whole plant incl. BoS/BoP/cooling
    10 / 1003099.999——commercial
    A

    Source
    Source notes

    Nel PEM 100 Standard Plant Solution Rev B · Accessed 2026-11-05

    20,200 Nm3/h; whole plant 5.0 kWh/Nm3; stack 52.5 kWh/kg; purity with optional dryer

    Nel HydrogenPSM (10 MW class)Containerised modular skidPEM10181.652.3
    Reference used
    stack at 100% capacity; system not given
    10 / 1003099—10commercial
    A

    Vendor kWh/kg is not a system-level figure – shown, but H2Hub reference efficiency used in simulation

    Source
    Source notes

    Nel PSM Series Rev A · Accessed 2026-11-05

    2,020 Nm3/h; >99% wet gas; ramp up to 10%/s

    Nel HydrogenMC250Containerised outdoorPEM1.2522.156.7
    Used in simulation
    system (stack 52.3)
    10 / 1003099.95—15.9commercial
    A

    Older document

    Source
    Source notes

    Nel MC Series Spec Sheet Rev G (2021) · Accessed 2026-11-05

    246 Nm3/h; 2021 sheet, check still offered

    Plug PowerGenEco EX-2125D (5 MW)Containerised turnkeyPEM589.949.9
    Reference used
    stack average
    — / —4099.999—13commercial
    A

    Vendor kWh/kg is not a system-level figure – shown, but H2Hub reference efficiency used in simulation; Older document

    Source
    Source notes

    Plug EX-2125D spec sheet (c. 2021-22) · Accessed 2026-11-05

    1,000 Nm3/h; 2,125 kg/day; older sheet

    Quest One (MAN)ME45040 ft container ~36 tPEM118.952.3
    Used in simulation
    system; BoL; HHV; 200 Nm3/h at 30 barg
    20 / 1003099.999——commercial
    B

    Source
    Source notes

    Quest One ME450 datasheet Rev 2.0 (distributor-hosted) · Accessed 2026-11-05

    210 Nm3/h nominal; 4.7 kWh/Nm3; 75% system efficiency; pressure as published: 20-30

    Neuman & EsserNEA HYTRON PEM 1 MW stack module40 ft containerPEM118—
    Reference used
    basis not stated
    — / —3099.9999——commercial
    B

    No kWh/kg published – H2Hub reference used

    Source
    Source notes

    NEA HYTRON datasheet (Hyfindr-hosted) · Accessed 2026-11-05

    Up to 200 Nm3/h per stack; pressure >30 bar; no energy figure

    BoschHybrion PEM stackStack; container plants up to 5 MWPEM1.252352.3
    Reference used
    basis not stated
    — / —34———early-commercial
    C

    Vendor kWh/kg is not a system-level figure – shown, but H2Hub reference efficiency used in simulation; Not from manufacturer

    Source
    Source notes

    ingenieur.de: Bosch Bamberg electrolyser (Nov 2025) · Accessed 2026-11-05

    Trade press; 4.7 kWh/Nm3; 10-year lifetime claim (not stack hours); pressure as published: <34

    Schaeffler1 MW PEM stackStack (50 kW-1 MW)Browse-only · No – not a sold productPEM118.8—
    Reference used
    basis not stated
    — / —————announced
    C

    No kWh/kg published – H2Hub reference used; Not from manufacturer

    Source
    Source notes

    Hydrogen Central: Schaeffler (Apr 2025) · Accessed 2026-11-05

    Trade press; ~450 kg/day; no efficiency

    VerdagyeDynamic20 MW building blockAlkaline20—41–51 · range
    Reference used
    basis not stated
    5 / 100————early-commercial
    B

    Vendor kWh/kg is not a system-level figure – shown, but H2Hub reference efficiency used in simulation

    Source
    Source notes

    Verdagy eDynamic page · Accessed 2026-11-05

    Single-cell AWE; 5-100% in <2 min; claims no stack replacements

    Stiesdal HydrogenHydroGen 3.1 MWModular outdoor pressurised unitAlkaline3.157.5—
    Reference used
    basis not stated
    25 / 10035———commercial
    C

    No kWh/kg published – H2Hub reference used; Not from manufacturer

    Source
    Source notes

    Hyfindr: Stiesdal HydroGen · Accessed 2026-11-05

    Marketplace; ramp 1%/s; 6.5 MW model launched May 2026 without specs; pressure as published: <35

    HydrogenProGen 3 pressurised alkalinePressurised alkaline stacksAlkaline——50.1
    Reference used
    basis not stated; BoL expected
    — / —————commercial
    C

    Vendor kWh/kg is not a system-level figure – shown, but H2Hub reference efficiency used in simulation; Not from manufacturer

    Source
    Source notes

    HydrogenPro Q2 2025 presentation · Accessed 2026-11-05

    Investor presentation not datasheet; 4.5 kWh/Nm3 BoL expected

    0 / 4 selected

    Vendor-published figures, not performance guarantees. Confirm with the manufacturer before procurement.

    Preliminary model result. Results are estimates derived from your inputs, stated assumptions and third-party data. Actual project economics may differ materially. This is project-economics analysis, not personalised investment advice or a lender term sheet.