Electrolyser dispatch and technology fit
Vendor models
64 of 64 models · 41 brands| Select | Brand / model | Technology | Unit MW | H₂ kg/h | Specific energy kWh/kg / basis | Min / max load % | Pressure bar | Purity % | Stack life h | Water L/kg | Status | Source / review |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens EnergyElyzer P-300 (formerly Silyzer 300)Prefabricated skids; 24-stack array; indoor | PEM | 17.5 | 335 | — Reference used — | 40 / 100 | — | 99.999 | 80000 | 10 | commercial | A No kWh/kg published – H2Hub reference used SourceSource notesSiemens Energy Electrolyzer Brochure (2026) · Accessed 2026-11-05 Plant efficiency >75.5% (basis not stated) so kWh/kg blank; min load per stack; 80k h design life; pressure customised | |
| Siemens EnergyElyzer P-360Modular skids; ~50 MW; 48x20 m | PEM | 50 | 920 | 55.5 · upper bound Used in simulation system AC incl. power electronics; upper bound | 40 / 100 | 10 | 99.999 | — | 10 | early-commercial | A Source Source notesSiemens Energy Elyzer P-360 Factsheet (2026) · Accessed 2026-11-05 Pressurised P-300 successor; 10 bara; approx figures | |
| Nel HydrogenMC500Containerised 40ft + 20ft power | PEM | 2.5 | 44.23 | 56.73 Used in simulation system; stack 52.28 | 10 / 100 | 30 | 99.95 | — | 15.9 | commercial | A Older document SourceSource notesNel MC Series Spec Sheet Rev G (2021) · Accessed 2026-11-05 492 Nm3/h and 5.1 kWh/Nm3 converted; 2021 sheet, current sales not confirmed | |
| ITM PowerNEPTUNE VContainerised; 8 stacks | PEM | 5 | 90 | 55.9 Used in simulation system AC incl. water purification + BoP; BOL | 12.5 / 100 | 30 | — | — | — | commercial | A Source Source notesITM Power NEPTUNE V Spec Sheet 2.8 · Accessed 2026-11-05 Purity <5 ppm H2O/O2 (ISO 14687) | |
| ITM PowerNEPTUNE IIContainerised; 3 stacks | PEM | 2 | 35 | 57 Used in simulation system AC incl. water purification + BoP; BOL | 25 / 100 | 30 | — | — | — | commercial | A Source Source notesITM Power NEPTUNE II Spec Sheet 2.13 · Accessed 2026-11-05 Purity <5 ppm H2O/O2 | |
| ITM PowerPOSEIDONSkid-mounted; 30 TRIDENT stacks | PEM | 20 | 360 | 55.9 Used in simulation system AC incl. water purification + BoP; BOL | 20 / 100 | 31 | — | — | — | commercial | A Source Source notesITM Power POSEIDON Data Sheet 2.7 · Accessed 2026-11-05 Water-saturated output | |
| ITM PowerTRIDENT (2 MW skid)Skid with 3 stacks | PEM | 2 | 36 | — Reference used — | 25 / 100 | 31 | — | — | — | commercial | C No kWh/kg published – H2Hub reference used; Not from manufacturer SourceSource notesTRIDENT Data Sheet 2.1 A (third-party copy) · Accessed 2026-11-05 Third-party copy of ITM sheet; no specific energy | |
| Plug PowerGenEco 10 MWModular; ~117 m2 | PEM | 10 | 179.8 | 49.9 Reference used average stack; BOL not stated | — / — | 40 | 99.999 | — | 13 | commercial | A Vendor kWh/kg is not a system-level figure – shown, but H2Hub reference efficiency used in simulation SourceSource notesPlug GenEco 10 MW datasheet · Accessed 2026-11-05 2000 Nm3/h converted; STACK figure, not system | |
| Accelera (Cummins)HyLYZER 1000-30Containerised; 2 stacksBrowse-only · No – discontinued | PEM | 5 | 90 | 52 Reference used system BOL nominal | 15 / 100 | 30 | 99.9 | — | 9 | discontinued | B Source Source notesAccelera HyLYZER 1000 product page · Accessed 2026-11-05 Cummins halted new electrolyzer sales Feb 2026 (trade press) | |
| Electric HydrogenHYPRPlantOpen-air integrated plant 75-120 MW | PEM | 100 | 1900 | 45.2–54.3 · range Used in simulation system BOL at AC into plant transformers; range | — / — | 32 | 99.9 | — | 13 | commercial | A Older document SourceSource notesEH2 Technical Specification Sheet (Aug 2023) · Accessed 2026-11-05 Peak BOL output; 2023 sheet | |
| Quest One (MAN)MHP 10 MW blockSkid-mounted block; indoor | PEM | 10 | 191.5 | 51 Reference used stacks + converters; BOL; HHV | 10 / 100 | 30 | 99.999 | — | — | commercial | B Vendor kWh/kg is not a system-level figure – shown, but H2Hub reference efficiency used in simulation SourceSource notesQuest One MHP product page · Accessed 2026-11-05 2130 Nm3/h converted; 5.0 purity with option; formerly H-TEC Systems | |
| OhmiumLotus MK3Outdoor modular rack units | PEM | — | — | 48 Used in simulation system AC BOL | — / — | — | — | — | — | commercial | B Source Source notesOhmium Products page · Accessed 2026-11-05 Only specific energy published | |
| HystarVega 1000Containerised | PEM | 5 | 92.1 | 50.7 Used in simulation system incl. power unit; 100% load; 4 barg; BOL | 0 / 100 | 45 | — | — | — | early-commercial | B Source Source notesHystar Vega product page · Accessed 2026-11-05 Headline 48.8; 52.7 at 30 barg; stack 47.5 | |
| HystarOrion 20000Skid-based 20 MW cluster | PEM | 20 | 368 | 48.2 Reference used cluster; basis unclear | — / — | — | — | — | — | early-commercial | B Vendor kWh/kg is not a system-level figure – shown, but H2Hub reference efficiency used in simulation; Published figures inconsistent – confirm with vendor SourceSource notesHystar Orion product page · Accessed 2026-11-05 CHECK: 48.2 kWh/kg inconsistent with 20 MW / 368 kg/h | |
| Sungrow HydrogenPEM 500 Nm3/h40ft container | PEM | — | 44.95 | 50.06 Used in simulation system AC BOL nominal; stack DC 47.83 | 5 / 110 | 30 | 99.999 | — | 10.01 | commercial | A Source Source notesSungrow PEM datasheet (Feb 2025) · Accessed 2026-11-05 500 Nm3/h converted; purity after purification | |
| thyssenkrupp nucerascalum 20 MW AWE unitPrefabricated skid-mounted modular plant | Alkaline | 20 | 359.6 | 50.06 Reference used DC at start-up; expected values | 10 / 100 | 0.3 | 99.9 | — | — | commercial | A Vendor kWh/kg is not a system-level figure – shown, but H2Hub reference efficiency used in simulation SourceSource notesthyssenkrupp nucera Green Hydrogen brochure (Oct 2024) · Accessed 2026-11-05 4000 Nm3/h; 4.5 kWh/Nm3 DC expected; near-atmospheric | |
| Nel HydrogenA485 (A-Series atmospheric)Modular atmospheric system | Alkaline | 2.5 | 43.58 | 50.06 Reference used stack; DC/AC not stated | 15 / 100 | 0.03 | — | — | — | commercial | A Vendor kWh/kg is not a system-level figure – shown, but H2Hub reference efficiency used in simulation SourceSource notesNel A Series Spec Sheet DOC001974_03 · Accessed 2026-11-05 485 Nm3/h max; 50 ±1.1 kWh/kg at stack, 100% load; turndown 15-100%; no system figure published | |
| Nel HydrogenAWE 100 Standard PlantStandard 100 MW atmospheric plant | Alkaline | 100 | 1744.06 | 51.1 Used in simulation plant AC; nominal | 15 / 100 | 0.03 | 99.99 | — | — | commercial | A Source Source notesNel AWE 100 Standard Plant Solution · Accessed 2026-11-05 Stack DC 49 kWh/kg; plant 51.1; purity with optional purification | |
| Nel HydrogenPressurised Alkaline (PAE) 25 MWOutdoor, 230 m2 | Alkaline | 25 | 416.69 | 50.8–53.2 · range Used in simulation system BOL | 12.5 / 100 | 15 | 99.5 | — | — | early-commercial | A Source Source notesNel datasheet PAE (May 2026) · Accessed 2026-11-05 Stack BOL 48.8-51.2; degradation 1-1.5%/yr; launched May 2026 | |
| John Cockerill HydrogenDQ1000Pressurised single-stack unit | Alkaline | 5 | 89.9 | — Reference used stack DC 44.49-47.83 kWh/kg; system not stated | 40 / 100 | 30 | 99.8 | — | 10.23 | commercial | A No kWh/kg published – H2Hub reference used; Older document SourceSource notesJohn Cockerill DQ1000 datasheet (2023) · Accessed 2026-11-05 1000 Nm3/h; 5 MW plant AC; 99.999% after purification | |
| Stargate HydrogenAurora 10 MW moduleOutdoor module, 2x5 MW stacks | Alkaline | 10 | — | 49 · upper bound Reference used stack | — / — | — | — | — | — | early-commercial | C Vendor kWh/kg is not a system-level figure – shown, but H2Hub reference efficiency used in simulation; Not from manufacturer SourceSource notesH2 Tech: Stargate Aurora (Oct 2025) · Accessed 2026-11-05 Trade press; no maker datasheet | |
| McPhyMcLyzer 800-30Core moduleBrowse-only · No – discontinued | Alkaline | 4 | 71.92 | 50.06 Reference used DC nominal | — / — | 30 | — | — | — | discontinued | C Vendor kWh/kg is not a system-level figure – shown, but H2Hub reference efficiency used in simulation; Not from manufacturer; Older document SourceSource notesMcPhy McLyzer portfolio (2020) · Accessed 2026-11-05 McPhy liquidated 2025; John Cockerill took most assets | |
| SunfireHyLink Alkaline 23 (50 MW)Outdoor skid module, 10x5 MW stacks | Alkaline | 50 | 1000 | 46.5–52.3 · range Used in simulation total AC | 20 / 100 | 30 | 99.8 | — | — | early-commercial | A Source Source notesSunfire HyLink Alkaline 23 fact sheet (Apr 2026) · Accessed 2026-11-05 50 MW DC rating; 67% LHV DC; stack mechanical life 10 yr; ramp 4%/s | |
| SunfireHyLink Alkaline 22 (10 MW)10 MW module | Alkaline | 10 | — | — Reference used stack 67% LHV DC; no kWh/kg | — / — | 30 | — | — | — | commercial | B No kWh/kg published – H2Hub reference used SourceSource notesSunfire HyLink Alkaline page · Accessed 2026-11-05 No fact sheet; output not stated | |
| LONGi HydrogenALK G seriesStandardised series | Alkaline | — | 107.88–269.7 | 47.83–50.06 · range Reference used DC | 30 / 110 | 16 | — | — | — | commercial | B Vendor kWh/kg is not a system-level figure – shown, but H2Hub reference efficiency used in simulation; Published life figure is service/design life, not stack life – H2Hub reference stack life used SourceSource notesLONGi ALK G product page · Accessed 2026-11-05 1200-3000 Nm3/h; 200000 h is service life not stack life | |
| LONGi HydrogenALK Hi1 Plus 1000Single unit | Alkaline | — | 89.9 | 45.61 Reference used DC | 30 / 110 | 16 | 99.999 | — | — | commercial | A Vendor kWh/kg is not a system-level figure – shown, but H2Hub reference efficiency used in simulation SourceSource notesLONGi Hi1 datasheet · Accessed 2026-11-05 <=4.1 kWh/Nm3; purity after purification | |
| Sungrow HydrogenALK 1000 Nm3/hSeparation + purification skids | Alkaline | — | 89.9 | 51.17 Used in simulation system AC BOL nominal | 25 / 110 | 16 | 99.8 | — | 10.01 | commercial | A Source Source notesSungrow ALK datasheet (Feb 2025) · Accessed 2026-11-05 Stack DC BOL 50.06; ramp 5%/s | |
| Sungrow HydrogenALK 500 Nm3/hSeparation + purification skids | Alkaline | — | 44.95 | 51.72 Used in simulation system AC BOL nominal | 25 / 110 | 16 | 99.8 | — | 10.01 | commercial | A Source Source notesSungrow ALK datasheet (Feb 2025) · Accessed 2026-11-05 Stack DC BOL 50.06 | |
| Trina HydrogenOne Series AWE 2000Single unit | Alkaline | — | 179.8 | 44.49–48.94 · range Reference used basis not stated | 30 / 110 | 16 | — | — | — | commercial | C Vendor kWh/kg is not a system-level figure – shown, but H2Hub reference efficiency used in simulation; Not from manufacturer SourceSource notesHyfindr listing: AWE 2000 · Accessed 2026-11-05 Marketplace source, not manufacturer | |
| Bloom EnergyBloom Electrolyzer (1.2 MW block)modular block in 1.2 MW steps | SOEC | 1.2 | 32 | 37.5 Used in simulation system; electricity; external steam supplied (4.5-5.5 barg, 150-200 C), steam heat not quantified | — / — | 0.025 | — | — | 10.5 | commercial | A Needs external steam/heat; Older document SourceSource notesBloom Energy Electrolyzer datasheet (Dec 2023) · Accessed 2026-11-05 25 mbar(g) output; product gas 85% H2/15% H2O (not dried); datasheet states 37.5+ | |
| Bloom EnergyBloom Electrolyzer (4 MW)modular | SOEC | 4 | 100 | 37.5 Used in simulation system; steam/heat basis not stated | — / — | — | — | — | — | commercial | B Needs external steam/heat SourceSource notesBloom Energy - Electrolyzers · Accessed 2026-11-05 Over 2.4 t/day (100 kg/h is lower bound); 37.5 from INL pilot; SOEC range 37-44 stated | |
| SunfireHyLink SOEC (GEN 3)pre-assembled outdoor module 34 x 7.5 m | SOEC | 10 | 291 | — Reference used system AC; 89% LHV expected GEN 3; needs LP steam >150 C | 50 / 100 | — | — | — | — | early-commercial | B No kWh/kg published – H2Hub reference used; Needs external steam/heat SourceSource notesSunfire HyLink SOEC product page · Accessed 2026-11-05 No kWh/kg published (efficiency only); ramp 10%/min; ISO 14687 Grade B after drying | |
| TopsoeSOEC core (demo)cell>stack>core>sectionBrowse-only · No – demo figures, no product datasheet | SOEC | 0.35 | — | 36 Reference used core level; electricity; demo; upper bound | — / 105 | 3.5 | — | — | — | demo | B Vendor kWh/kg is not a system-level figure – shown, but H2Hub reference efficiency used in simulation; Needs external steam/heat SourceSource notesTopsoe SOEC demo results · Accessed 2026-11-05 Demo figures not datasheet; <36 kWh/kg; 2,250 h test only | |
| ElcogenSOEC stackstack componentBrowse-only · No – not a sold product | SOEC | — | — | 33 Reference used stack claim; electricity | — / — | — | — | — | — | announced | C Vendor kWh/kg is not a system-level figure – shown, but H2Hub reference efficiency used in simulation; Needs external steam/heat; Not from manufacturer SourceSource notesHydrogen Insight - Elcogen 350MW factory · Accessed 2026-11-05 Trade press; stack supplier only; company claim | |
| Ceres10 MW pressurised SOEC module (Shell design)module (licensed design)Browse-only · No – not a sold product | SOEC | 10 | — | 36 Reference used module level; target | — / — | — | — | — | — | announced | C Vendor kWh/kg is not a system-level figure – shown, but H2Hub reference efficiency used in simulation; Needs external steam/heat; Not from manufacturer SourceSource notesCeres signs contract with Shell · Accessed 2026-11-05 Licensor; target value, not product | |
| EnapterAEM Nexus 1000containerised 40 ftBrowse-only · Library only – no AEM reference profile yet | AEM | 0.9332 | 18.2 | 51.3 Reference used system incl. utilities; BoL full load | 8.5 / 100 | 31 | 99.5 | — | 8.98 | commercial | A Source Source notesDatasheet AEM Nexus 1000 (15.06.2026) · Accessed 2026-11-05 202 Nm3/h; 4.61 kWh/Nm3; purity up to 99.999% with dryer | |
| EnapterAEM Flex 120skid 6 x 2.5 mBrowse-only · Library only – no AEM reference profile yet | AEM | 0.112 | 2.16 | 51.3 Reference used system incl. utilities; BoL full load | 12 / 100 | 31 | 99.5 | — | 8.98 | commercial | A Source Source notesDatasheet AEM Flex 120 (15.06.2026) · Accessed 2026-11-05 24.1 Nm3/h; 4.61 kWh/Nm3 | |
| EnapterEL 4.1 (AC/LC)19-inch rack 6UBrowse-only · Library only – no AEM reference profile yet | AEM | 0.0024 | 0.045 | 53.4 Reference used basis not stated; BoL | — / — | 35 | 99.9 | — | 9.34 | commercial | A Vendor kWh/kg is not a system-level figure – shown, but H2Hub reference efficiency used in simulation SourceSource notesData Sheet EL 4 AC LC · Accessed 2026-11-05 0.5 Nm3/h at 4.8 kWh/Nm3 converted | |
| PERIC Hydrogen (718th Institute)CDQ series (CDQ16-CDQ1000)skid-mounted | Alkaline | — | 1.8–179.8 | 47.83 · upper bound Reference used DC; stack vs system not stated | — / — | — | 99.8 | — | — | commercial | B Vendor kWh/kg is not a system-level figure – shown, but H2Hub reference efficiency used in simulation SourceSource notesPERIC Hydrogen - Alkaline type · Accessed 2026-11-05 20-2000 Nm3/h; <=4.3 kWh/Nm3 DC; purity >99.8% initial | |
| ShuangliangSLZQ-2000stack 6.0x2.5x2.8 m | Alkaline | — | 179.8 | 43.38–50.06 · range Reference used DC; stack vs system not stated | 20 / 110 | 40 | 99.9999 | — | — | commercial | B Vendor kWh/kg is not a system-level figure – shown, but H2Hub reference efficiency used in simulation; Published life figure is service/design life, not stack life – H2Hub reference stack life used SourceSource notesShuangliang - Alkaline Water Electrolyzer · Accessed 2026-11-05 3.9-4.5 kWh/Nm3 DC; purity with purification; 1.6-4.0 MPa; service life >=160000 h (not stack life); pressure as published: 16-40 | |
| Cockerill Jingli HydrogenDQ-1000/1.6pressurised filter-press bipolar | Alkaline | — | — | — Reference used DC; stack vs system not stated | — / — | 16 | — | — | — | commercial | B No kWh/kg published – H2Hub reference used SourceSource notesCockerill Jingli Hydrogen - Alkaline electrolysis · Accessed 2026-11-05 Output and energy units unclear on source, left blank; 21 models DQ-2 to DQ-1500 | |
| Hygreen EnergyHG200integrated frame | Alkaline | 1 | 17.98 | — Reference used — | 30 / 110 | 32 | 99.999 | — | — | commercial | B No kWh/kg published – H2Hub reference used SourceSource notesHygreen Energy - Alkaline · Accessed 2026-11-05 200 Nm3/h; line-level load and pressure; no energy figure; pressure as published: <32 | |
| Hygreen EnergyPEM electrolyser linecontainerised or custom plant | PEM | 1.5 | — | 47.83 Reference used DC; stack vs system not stated | 5 / 110 | — | — | — | — | commercial | B Vendor kWh/kg is not a system-level figure – shown, but H2Hub reference efficiency used in simulation SourceSource notesHygreen Energy - PEM · Accessed 2026-11-05 Stack up to 1.5 MW; 4.3 kWh/Nm3; power as published: <1.5 | |
| Hygreen EnergyAEM electrolyser linecontainerised turnkeyBrowse-only · Library only – no AEM reference profile yet | AEM | 0.5 | 8.99 | 48.94 Reference used DC; stack vs system not stated | 10 / 120 | — | — | — | — | early-commercial | B Vendor kWh/kg is not a system-level figure – shown, but H2Hub reference efficiency used in simulation SourceSource notesHygreen Energy - AEM · Accessed 2026-11-05 Stack up to 500 kW / 100 Nm3/h; 4.4 kWh/Nm3; status judged; power as published: <0.5 | |
| Shanghai Electric (Hydrogen Era)QQSD-Z series | Alkaline | — | 4.5–179.8 | 47.39 Reference used DC; stack vs system not stated | 20 / 167 | — | — | — | — | early-commercial | C Vendor kWh/kg is not a system-level figure – shown, but H2Hub reference efficiency used in simulation; Not from manufacturer SourceSource notesHuanqiu Tech on Shanghai Electric QQSD-Z · Accessed 2026-11-05 Trade press (Mar 2024); 50-2000 Nm3/h; 4.26 kWh/Nm3 DC rated | |
| Mingyang HydrogenMYH-K-1000 | Alkaline | — | — | — Reference used DC; stack vs system not stated | 20 / 120 | — | — | — | — | early-commercial | C No kWh/kg published – H2Hub reference used; Not from manufacturer SourceSource notesSMM: Mingyang MYH-K-1000 Frontrunner evaluation · Accessed 2026-11-05 Trade press (Mar 2026); 1000 Nm3/h class; energy unit basis unclear | |
| Guofu Hydrogen2000 Nm3 alkaline unit | Alkaline | — | — | 46.72 · upper bound Reference used DC; stack vs system not stated | 20 / — | — | — | — | — | early-commercial | C Vendor kWh/kg is not a system-level figure – shown, but H2Hub reference efficiency used in simulation; Not from manufacturer SourceSource notesSMM: Guofu 2000 Nm3 alkaline electrolyser · Accessed 2026-11-05 Trade press (Sep 2026); <=4.2 kWh/Nm3 DC at 4000 A/m2 | |
| CRRCWide Power Range Adjustable Electrolyzer (1000 Nm3/h)electrolyser + separation/purification unit | Alkaline | — | 89.9 | 48.94 · upper bound Reference used DC; stack vs system not stated | 25 / 110 | 16 | 99.999 | — | — | commercial | B Vendor kWh/kg is not a system-level figure – shown, but H2Hub reference efficiency used in simulation SourceSource notesCRRC Wide Power Range Adjustable Electrolyzer · Accessed 2026-11-05 CRRC group domain (Apr 2025); <=4.4 kWh/Nm3 DC; purity after purification | |
| SPIC Hydrogen Energy Technology500 Nm3/h PEM electrolyser | PEM | — | 44.95 | 48.94 Reference used basis not stated | — / — | — | — | — | — | early-commercial | C Vendor kWh/kg is not a system-level figure – shown, but H2Hub reference efficiency used in simulation; Not from manufacturer SourceSource notesFuelCellChina: SPIC 500 Nm3/h PEM certification · Accessed 2026-11-05 Trade press (Oct 2024); 4.4 kWh/Nm3 at 1.8 A/cm2 | |
| Shanghai H-Ray S&TPEM stack 100-250 Nm3/hstack | PEM | — | 8.99–22.48 | 45.61 Reference used DC; stack vs system not stated | 10 / 120 | — | — | — | — | commercial | C Vendor kWh/kg is not a system-level figure – shown, but H2Hub reference efficiency used in simulation; Published life figure is service/design life, not stack life – H2Hub reference stack life used; Not from manufacturer SourceSource notesHyfindr: H-Ray PEM stack · Accessed 2026-11-05 Marketplace; 4.1 kWh/Nm3 DC; design lifetime >=80000 h (not stated as stack life) | |
| Asahi KaseiAqualyzer-C3containerised | Alkaline | 1 | — | — Reference used — | — / — | — | — | — | — | commercial | C No kWh/kg published – H2Hub reference used; Not from manufacturer SourceSource notesAsahi Kasei containerised electrolyser Finland (Business Wire) · Accessed 2026-11-05 Press release (Mar 2026); 1 MW class; 400 kg/day; C3 range 1-7.5 MW | |
| Kanadevia (formerly Hitachi Zosen)HYDROSPRING 200 Nm3/hpackage unit | PEM | — | 17.98 | 55.62 Reference used AC; stack vs system not stated | — / — | 8.5 | 99.999 | — | 11.12 | commercial | B Vendor kWh/kg is not a system-level figure – shown, but H2Hub reference efficiency used in simulation SourceSource notesKanadevia - Hydrogen Generator · Accessed 2026-11-05 5.0 kWh-AC/Nm3; 0.8-0.85 MPaG; pressure as published: 8-8.5; purity as published: 99.9-99.999 | |
| G-PhilosModular P2G ALK Linked 1Mmodular 10 kW stack modules | Alkaline | 1 | 17.98 | 53.88 Used in simulation system (stack 50.07); DC/AC not stated | — / — | 7 | 99.999 | — | 10 | commercial | C Published figures inconsistent – confirm with vendor; Not from manufacturer SourceSource notesHyfindr: G-Philos ALK Linked · Accessed 2026-11-05 Marketplace; listing internally inconsistent; status not stated | |
| Nel HydrogenPEM 100 Standard PlantStandard outdoor plant; 96 x 69 m | PEM | 100 | 1816 | 55.6 Used in simulation system – whole plant incl. BoS/BoP/cooling | 10 / 100 | 30 | 99.999 | — | — | commercial | A Source Source notesNel PEM 100 Standard Plant Solution Rev B · Accessed 2026-11-05 20,200 Nm3/h; whole plant 5.0 kWh/Nm3; stack 52.5 kWh/kg; purity with optional dryer | |
| Nel HydrogenPSM (10 MW class)Containerised modular skid | PEM | 10 | 181.6 | 52.3 Reference used stack at 100% capacity; system not given | 10 / 100 | 30 | 99 | — | 10 | commercial | A Vendor kWh/kg is not a system-level figure – shown, but H2Hub reference efficiency used in simulation SourceSource notesNel PSM Series Rev A · Accessed 2026-11-05 2,020 Nm3/h; >99% wet gas; ramp up to 10%/s | |
| Nel HydrogenMC250Containerised outdoor | PEM | 1.25 | 22.1 | 56.7 Used in simulation system (stack 52.3) | 10 / 100 | 30 | 99.95 | — | 15.9 | commercial | A Older document SourceSource notesNel MC Series Spec Sheet Rev G (2021) · Accessed 2026-11-05 246 Nm3/h; 2021 sheet, check still offered | |
| Plug PowerGenEco EX-2125D (5 MW)Containerised turnkey | PEM | 5 | 89.9 | 49.9 Reference used stack average | — / — | 40 | 99.999 | — | 13 | commercial | A Vendor kWh/kg is not a system-level figure – shown, but H2Hub reference efficiency used in simulation; Older document SourceSource notesPlug EX-2125D spec sheet (c. 2021-22) · Accessed 2026-11-05 1,000 Nm3/h; 2,125 kg/day; older sheet | |
| Quest One (MAN)ME45040 ft container ~36 t | PEM | 1 | 18.9 | 52.3 Used in simulation system; BoL; HHV; 200 Nm3/h at 30 barg | 20 / 100 | 30 | 99.999 | — | — | commercial | B Source Source notesQuest One ME450 datasheet Rev 2.0 (distributor-hosted) · Accessed 2026-11-05 210 Nm3/h nominal; 4.7 kWh/Nm3; 75% system efficiency; pressure as published: 20-30 | |
| Neuman & EsserNEA HYTRON PEM 1 MW stack module40 ft container | PEM | 1 | 18 | — Reference used basis not stated | — / — | 30 | 99.9999 | — | — | commercial | B No kWh/kg published – H2Hub reference used SourceSource notesNEA HYTRON datasheet (Hyfindr-hosted) · Accessed 2026-11-05 Up to 200 Nm3/h per stack; pressure >30 bar; no energy figure | |
| BoschHybrion PEM stackStack; container plants up to 5 MW | PEM | 1.25 | 23 | 52.3 Reference used basis not stated | — / — | 34 | — | — | — | early-commercial | C Vendor kWh/kg is not a system-level figure – shown, but H2Hub reference efficiency used in simulation; Not from manufacturer SourceSource notesingenieur.de: Bosch Bamberg electrolyser (Nov 2025) · Accessed 2026-11-05 Trade press; 4.7 kWh/Nm3; 10-year lifetime claim (not stack hours); pressure as published: <34 | |
| Schaeffler1 MW PEM stackStack (50 kW-1 MW)Browse-only · No – not a sold product | PEM | 1 | 18.8 | — Reference used basis not stated | — / — | — | — | — | — | announced | C No kWh/kg published – H2Hub reference used; Not from manufacturer SourceSource notesHydrogen Central: Schaeffler (Apr 2025) · Accessed 2026-11-05 Trade press; ~450 kg/day; no efficiency | |
| VerdagyeDynamic20 MW building block | Alkaline | 20 | — | 41–51 · range Reference used basis not stated | 5 / 100 | — | — | — | — | early-commercial | B Vendor kWh/kg is not a system-level figure – shown, but H2Hub reference efficiency used in simulation SourceSource notesVerdagy eDynamic page · Accessed 2026-11-05 Single-cell AWE; 5-100% in <2 min; claims no stack replacements | |
| Stiesdal HydrogenHydroGen 3.1 MWModular outdoor pressurised unit | Alkaline | 3.1 | 57.5 | — Reference used basis not stated | 25 / 100 | 35 | — | — | — | commercial | C No kWh/kg published – H2Hub reference used; Not from manufacturer SourceSource notesHyfindr: Stiesdal HydroGen · Accessed 2026-11-05 Marketplace; ramp 1%/s; 6.5 MW model launched May 2026 without specs; pressure as published: <35 | |
| HydrogenProGen 3 pressurised alkalinePressurised alkaline stacks | Alkaline | — | — | 50.1 Reference used basis not stated; BoL expected | — / — | — | — | — | — | commercial | C Vendor kWh/kg is not a system-level figure – shown, but H2Hub reference efficiency used in simulation; Not from manufacturer SourceSource notesHydrogenPro Q2 2025 presentation · Accessed 2026-11-05 Investor presentation not datasheet; 4.5 kWh/Nm3 BoL expected |
Vendor-published figures, not performance guarantees. Confirm with the manufacturer before procurement.
Preliminary model result. Results are estimates derived from your inputs, stated assumptions and third-party data. Actual project economics may differ materially. This is project-economics analysis, not personalised investment advice or a lender term sheet.